Transformers
HSC Physics · Module 6: Electromagnetism
Transformers notes
Fact-checked by a second, independent AI review.
Understand how ideal transformers relate voltages, currents and turns, and how real transformers lose energy through core and copper losses.
- Turns ratio
- Voltage ratio equals the turns ratio: V1/V2 = N1/N2, and current ratio is I1/I2 = N2/N1 (for an ideal transformer).
- Power transfer (ideal)
- Power in equals power out: V1I1 = V2I2, with no losses in an ideal transformer.
- Ideal transformer core concept
- No losses in an ideal model; in reality core losses (hysteresis and eddy currents) reduce efficiency.
- Copper losses
- Resistance of windings causes copper loss; occurs as I^2R losses in the windings, reducing output power.
- Practical efficiency
- Efficiency η = Pout/Pin = (V2I2)/(V1I1); higher turns ratio can step voltage up or down, but losses limit real efficiency.
Remember it: “N up means V up; N down means V down” — keep turns ratio in mind to predict voltage changes.
Exam tip: Examiners want correct V1/V2 = N1/N2, I1/I2 = N2/N1, and recognition of losses (core and copper). Include a quick efficiency calculation and identify where energy is lost.
Syllabus checklist
- Ideal transformers
- Turns ratio
- Power transmission and energy loss
Practice questions
1. An ideal transformer with Np=400, Ns=100. If Vp=240 V, Vs= ?
Answer checked
Show answer
Answer: 60. Vs = Vp × Ns/Np = 240 × 100/400 = 60 V.
2. Frequency stays the same through an ideal transformer.
Answer checked
Show answer
Answer: True. An ideal transformer does not change frequency; it changes voltage and current.
3. In an ideal transformer, Vp Ip = Vs Is. If Vp=240 V, Vs=60 V, and Is=3 A, Ip = ____ A.
Answer checked
Show answer
Answer: 0.75. Ip = (Vs × Is)/Vp = (60×3)/240 = 0.75 A.
4. An ideal transformer steps down from 300 V to 150 V. If primary current is 1.2 A, what is secondary current Is?
Answer checked
Show answer
Answer: 2.40. Ip/Is = Ns/Np = Vs/Vp = 150/300 = 1/2, so Is = 2×Ip = 2.4 A.
5. Compute Ip (A) for an ideal transformer: Vp=240 V, Vs=60 V, Is=3 A.
Answer checked
Show answer
Answer: 0.75. Ip = (Vs × Is)/Vp = (60×3)/240 = 0.75 A.

Practise transformers as a game